Multi meter Digital 2670787
Datasheet
- Indication: Digital
- Analogue bargraph display: no
- Analogue bargraph display analogue/logarithmical: no
- Multiple display: no
- Measuring range selection: Manual
- Max. voltage measuring range, AC: 1000V
- Lowest resolution, AC voltage: 0.1 mV
- Max. voltage measuring range, DC: 1500V
- Lowest resolution, DC voltage: 0.1 mV
- Max. current measuring range, AC: 2A
- Lowest resolution, AC current: 0.01 µA
- Max. current measuring range, DC: 2A
- Lowest resolution, DC current: 0.01 µA
- Max. resistance measuring range: 40Mohm
- Milliohm measurement with 4 wire technique (Kelvin connection): no
- Lowest resolution, resistance: 0.1 Ohm
- Temperature measurement: yes
- Temperature measurement RTD: no
- Temperature measurement TC: no
- Max. temperature measuring range: 1300°C
- Capacitance measurement: yes
- Max. capacitance measuring range: 400µF
- Frequency measurement: yes
- Max. frequency measuring range: 10000kHz
- Resistance test/diode test: yes
- Isolation resistance measuring range: 40 - 40Mohm
- Nominal test voltage 10 V: no
- Nominal test voltage 50 V: no
- Nominal test voltage 100 V: no
- Nominal test voltage 250 V: no
- Nominal test voltage 500 V: no
- Nominal test voltage 1000 V: no
- Power and energy measurement: no
- Harmonics analysis/power quality: no
- With decibel measurement (dB): no
- Relative value measurement: yes
- Inductance measurement: no
- Conductivity measurement: no
- Continuity test: yes
- Data hold: yes
- Maximum value storage: yes
- Minimum value storage: yes
- Peak value memory: yes
- True RMS measurement: yes
- Duty cycle measurements: no
- Rotational speed measuring: no
- Measured value memory: yes
- Interface: no
- Bluetooth interface: no
- IR interface: no
- Automatic circuit breaker: no
- Measuring circuit category: CAT IV
- Max. voltage measuring circuit category: 1000V
- Explosion-tested version: no
Logistics
- Weight: 973 g
Stock
- 22.11.2024
- Shipping time: